|
|
Value of Lumen Enhanced CT Density of Dual Source CT Coronary Angiography in Evaluating Degree of Coronary Artery Stenosis and Influencing Factors |
WANG Manai |
Zhengzhou Yangcheng Hospital,Zhengzhou Henan 452470 |
|
|
Abstract 【Objective】To explore the value of lumen enhanced CT density of dual source CT coronary angiography in evaluating the degree of coronary artery stenosis, and analyze the relevant factors affecting the evaluation of coronary artery stenosis by dual source CT coronary angiography. 【Methods】The medical records of 102 patients with coronary artery stenosis admitted to our hospital from March 2019 to March 2022 were retrospectively analyzed. According to the degree of coronary artery stenosis, they were divided into mild stenosis group, moderate stenosis group and severe stenosis group. The CT enhanced density values of proximal and distal lumens were calculated by dual source CT coronary angiography. Spearman correlation analysis was used to analyze the correlation between intraluminal CT enhancement value and the degree of lumen stenosis. The area under the receiver operating characteristic (ROC) curve (AUC) was used to evaluate the value of enhanced CT density in evaluating the degree of intraluminal stenosis. In addition, logistic regression analysis was used to analyze the related factors affecting the evaluation of coronary stenosis by dual source CT coronary angiography. 【Results】Lumen enhanced CT density in the moderate stenosis and severe stenosis group were higher than that in the mild stenosis group (P<0.05). Spearman correlation analysis showed that the enhancement value of intraluminal CT was positively correlated with the degree of lumen stenosis (P<0.05). ROC analysis showed that the AUC of enhanced CT density value for ROC diagnosis of intraluminal stenosis was 0.842 (95%CI:0.756-0.929). Logistic stepwise multivariate regression analysis showed that Agatston score increased, heart rate variability >15 beats/min,body mass index >25 kg/m2,venous pollution,and the increase of contrast-enhanced density of intracavitary CT were risk factors for intervention of dual source CT coronary angiography to evaluate coronary stenosis (P<0.05). 【Conclusion】Lumen enhanced CT density can improve the accuracy of dual source CT coronary angiography in the evaluation of coronary artery stenosis.
|
Received: 26 December 2023
|
|
|
|
|
[1] 张昊,李萍. 双源CT诊断冠状动脉支架狭窄的临床应用分析[J].中国CT和MRI杂志,2020,18(9):96-99.
[2] 马颖,宁伟,梁进. 双源冠状动脉CTA在T2DM合并冠心病患者不同狭窄程度分级诊断中的应用价值[J].中国医药导报,2021,18(16):146-149.
[3] 刘云霏,马延贺,王常月,等. 双源CT评估冠状动脉钙化与病理诊断符合度[J].中国临床解剖学杂志,2021,39(6):649-653.
[4] 王新斌,刘芳,姜海兵,等. 双源CT冠状动脉造影对冠状动脉分支狭窄程度及其临界病变的诊断价值研究[J].安徽医药,2021,25(4):718-721.
[5] 任雪会,崔胜宏,马秀梅,等. 多层螺旋CT血管造影在评价冠状动脉粥样硬化性心脏病心肌缺血程度价值分析[J].中国CT和MRI杂志,2021,19(4):30-32.
[6] 黄群,李芳,胡绮莉,等. 管腔内CT值对冠状动脉狭窄程度的评估价值[J].同济大学学报(医学版),2021,42(2):248-253.
[7] 杨泉,杨勇,余建群,等. 冠状动脉CT造影狭窄程度预测患者远期预后的临床价值研究[J].中国全科医学,2020,23(12):1492-1496.
[8] 梁杉,王照谦. 腔内CT密度值用于评估冠状动脉钙化及狭窄程度[J].中国医学影像技术,2020,36(1):72-76.
[9] 马腾,洪芳艳,赵强. 冠状动脉CTA对患者冠脉狭窄程度、分叉病变的诊断分析研究[J].影像科学与光化学,2022,40(2):434-438.
[10] 粟丽,余建群,张丽芝. 改良的校正性腔内密度衰减值与冠状动脉狭窄程度及不同性质斑块在CT血管成像中的初步研究[J].心血管病学进展,2020,41(8):863-867.
[11] 海丹丹,王玲,张焕莉. CT动脉造影诊断冠状动脉支架内部再狭窄的意义及临床护理[J].医学影像学杂志,2022,32(1):72-75.
[12] 倪其鸣,虞凌明,焦静. 双源CT测量左心房功能参数在评估冠状动脉狭窄情况和左心室功能中的价值[J].现代医学,2019,47(11):1383-1386. |
|
|
|