Application Value of Portable Ultrasound-guided Central Venous Catheterization in Neurological Intensive Patients(a Case Report of its Rare Complication Attached)
ZHOU Li, PENG Yi
Department of Neurology, People's Hospital of Hunan Province, Changsha 410000,China
Abstract:【Objective】To explore the effect and safety of portable ultrasound-guided central venous catheterization. 【Methods】A total of 125 cases of central venous catheterization in our department were collected, 56 of which were used as the observation group, which was catheterized under portable ultrasound guidance, and the other 69 cases were used as the control group using traditional body surface markers to locate. Puncture success rate, complication rate, and puncture time were compared between the two groups. 【Results】The success rate of one puncture in the observation group was significantly higher than that in the control group [92.9%(52/56)vs 72.5%(50/69),P<0.05], the complication rate in the observation group was lower than that in the control group[0%(0/56) vs 11.6%(8/69),P<0.05], and the puncture time in the observation group was shorter than that in the control group [(8.31±1.41)min vs.(11.72±1.52)min,P<0.05]. A patient in the control group caused the guide wire to be incarcerated and could not be pulled out because the guide wire was mistakenly inserted into the transverse hole. After that, the guide wire was removed by surgery. 【Conclusion】Portable ultrasound can significantly improve the success rate of one-time puncture, shorten the puncture time, reduce the incidence of complications, and provide convenience for clinical treatment, which is worthy of wide promotion.
周栎, 彭熠. 便携式超声引导下中心静脉置管在神经内科重症患者中的应用(附罕见并发症一例报道)[J]. 医学临床研究, 2021, 38(7): 1031-1034.
ZHOU Li, PENG Yi. Application Value of Portable Ultrasound-guided Central Venous Catheterization in Neurological Intensive Patients(a Case Report of its Rare Complication Attached). JOURNAL OF CLINICAL RESEARCH, 2021, 38(7): 1031-1034.
[1] 张敏,夏燕飞.超声在中心静脉穿刺置管中的应用进展[J].现代实用医学,2021,33(2):145-146. [2] STEIN M, WAGNER R H. Komplikationen zentralvenöser Portsysteme:Erfahrungsbericht über 2359 Implantationen Complications of central venous access devices:outcome analysis of 2359 implantations[J].Dtsch Med Wochenschr,2005,130(18):1129-1132. [3] 张莹,于晖,赵楠楠,等.超声技术对中心静脉导管置管的安全性影响[J].中国医刊,2020,55(5):493-495. [4] 李玲,杨渊,殷环,等.我国慢性非传染性疾病流行态势研究[J].医学信息学杂志,2019,40(8):15-19. [5] 张晓婷,穆睿华,杨阳,等.两种输注方式在老年患者肠外营养中的效果观察[J].基层医学论坛,2018,22(24):3409-3410. [6] SHAPIRA M,STERN W Z.Hazards of subclavian vein cannulation for central venous pressure monitoring[J].JAMA,1967,201:327-329. [7] TURI G, TORDIGLIONE P, ARAIMO F.Case report:anterior mediastinal central line malposition[J].Anesth Analg,2013,117(1):123-125. [8] AMER A, BROADBENT R S, EDMONDS L, et al. Central venous catheter-related tachycardia in the newborn:case report and literature review[J].Case Rep Med,2016,2016:620-635. [9] 朱凤军,崔雨华,宋彦杰.中心静脉置管及并发症的防治体会[J].医学理论与实践,2012,25(19):2389-2390. [10] 霍建秋.中心静脉导管相关的常见并发症及处理[J].世界最新医学信息文摘,2015,15(74):46-48. [11] CALVERT N, HIND D, MCWILLIAMS R G, et al. The effectiveness and cost-effectiveness of ultrasound locating devices for centralvenous access:a systematic review and economic evaluation[J].Health Technol Assess,2003, 7(12):1-84. [12] 肖李锋,谢扬.便携式超声在创伤急救中的应用[J].创伤外科杂志,2019,21(2):151-153. [13] RATNASEKERA A,FERRADA P.Ultrasonographic guided resuscitation of the surgical patient[J].JAMA Surg,2018,153(1):77- 78. [14] NARULA J,CHANDRASHEKHAR Y.Time to add a fifth pillar to bedside physical examination:inspection,palpation,percussion,auscultation,and insonation[J].JAMA Cardiol,2018,3(4):346-350. [15] PAL R K, LAHA B, NANDY S, et al. Coiling of guide wire in the internal jugular vein during central venous catheter insertion:A rare complication[J].Indian J Anaesth,2014,58(6):786-788.